{"id":3980,"date":"2026-09-01T09:00:00","date_gmt":"2026-09-01T09:00:00","guid":{"rendered":"https:\/\/qmk-gmbh.de\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/"},"modified":"2026-11-24T17:05:10","modified_gmt":"2026-11-24T17:05:10","slug":"calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1","status":"publish","type":"post","link":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/","title":{"rendered":"Calibrating Vernier Calipers: Setup, Procedure, and Practical Application | #100 Measuring Instruments No. 1"},"content":{"rendered":"&#13;\n<p class=\"wp-block-paragraph\"><em>In our <strong>#100Messmittel<\/strong> series, we\u2019re showcasing 100 measuring and testing instruments that we calibrate every day here at QMK. We\u2019re kicking things off with a measuring tool that just about everyone has held in their hands at some point: the vernier caliper.<\/em><\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">\ud83d\udccf When someone asks me how tall I am, I say: 1,941,330 \u00b5m. Sound like an exaggeration? In our line of work, that\u2019s perfectly normal. We think in micrometers, not in \u201chundredths.\u201d And that\u2019s exactly why our series begins with the quintessential classic. After all, hardly any measuring tool is used as often\u2014and underestimated as often\u2014as the vernier caliper.<\/p>&#13;\n&#13;\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"626\" height=\"953\" class=\"wp-image-3969\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-koerpergroesse-messen.jpg\" alt=\"Measuring height with a 2-meter vernier caliper in the QMK calibration laboratory\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-koerpergroesse-messen.jpg 626w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-koerpergroesse-messen-197x300.jpg 197w\" sizes=\"(max-width: 626px) 100vw, 626px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">1,941,330 \u00b5m \u2013 measured with a vernier caliper.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">What is a vernier caliper?<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">The vernier caliper (also colloquially known as a \u201cslide gauge\u201d) is the all-purpose length-measuring tool in workshops, manufacturing, and quality assurance. With a single device, you can measure:<\/p>&#13;\n\r\n<ul class=\"wp-block-list\">&#13;\n<li><strong>External dimensions<\/strong> using external measuring probes, e.g., shaft diameters or material thicknesses<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Internal dimensions<\/strong> using the internal measuring probes, e.g., bores or grooves<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Depths<\/strong> using the depth measuring rod<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Steps and ledges<\/strong> via the end faces of the slide and rail<\/li>&#13;\n<\/ul>\r\n&#13;\n<h3 class=\"wp-block-heading\">Overview of Design Types<\/h3>&#13;\n\r\n<ul class=\"wp-block-list\">&#13;\n<li><strong>Vernier caliper:<\/strong> the classic model that doesn&#8217;t require batteries. Readings are taken using the vernier scale, in increments of 0.1 mm, 0.05 mm, or 0.02 mm, depending on the model.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Dial caliper:<\/strong> Readings are taken via a circular scale, which is quick and easy to read.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Digital calipers:<\/strong> Display with 0.01 mm resolution, often with a data interface for direct transfer to a CAQ system.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Special designs:<\/strong> long calipers extending well beyond 1,000 mm, depth calipers, calipers with tips, cutting edges, or for internal grooves.<\/li>&#13;\n<\/ul>\r\n&#13;\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"624\" height=\"940\" class=\"wp-image-3971\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/langer-digitaler-messschieber-endmasse.jpg\" alt=\"Long digital caliper with gauge blocks for calibration\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/langer-digitaler-messschieber-endmasse.jpg 624w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/langer-digitaler-messschieber-endmasse-199x300.jpg 199w\" sizes=\"(max-width: 624px) 100vw, 624px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">We also calibrate long vernier calipers\u2014here using gauge blocks in the lab.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Important: The smallest scale division does not necessarily indicate accuracy. Although a digital vernier caliper displays readings in hundredths, its actual measurement accuracy is determined by its calibration.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Common Sources of Error with Vernier Calipers<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Precisely because the vernier caliper is such a familiar tool, errors can creep in that go largely unnoticed in everyday use:<\/p>&#13;\n\r\n<ul class=\"wp-block-list\">&#13;\n<li><strong>Wear on the measuring jaws:<\/strong> Frequent measurements at the same spot\u2014usually near the tip of the jaw\u2014lead to wear and deformation of the measuring surfaces.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Tilt error (Abbe error):<\/strong> On a vernier caliper, the measured quantity and the measurement standard are not aligned. Thus, Abbe\u2019s comparator principle is not satisfied. If the caliper has play in the guide or if too much force is applied during measurement, the jaws tilt\u2014and the further forward on the jaws the measurement is taken, the less accurate the reading becomes.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Bent or warped rail:<\/strong> for example, after falling off a workbench.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Dirt and metal shavings<\/strong> in the guide or on the measuring system of digital devices.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Temperature:<\/strong> The reference temperature for length measurements is 20 \u00b0C. A caliper that has been left in the sun or near a hot machine will not give the same readings as one in an air-conditioned measurement room.<\/li>&#13;\n<\/ul>\r\n&#13;\n<h2 class=\"wp-block-heading\">How do we calibrate a vernier caliper?<\/h2>&#13;\n&#13;\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"660\" class=\"wp-image-3973\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk-1024x660.jpg\" alt=\"Calipers and gage pins before calibration at QMK\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk-1024x660.jpg 1024w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk-300x193.jpg 300w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk-768x495.jpg 768w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk.jpg 1383w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">Calipers and gage pins on their way to calibration.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">We base our calibration on the <strong>VDI\/VDE\/DGQ 2618 Part 9.1<\/strong> guideline (Test Equipment Control\u2014Testing Instructions for Calipers) in conjunction with the product standard <strong>DIN EN ISO 13385-1<\/strong>. An overview of the process:<\/p>&#13;\n\r\n<ol class=\"wp-block-list\">&#13;\n<li><strong>Cleaning and Temperature Control:<\/strong> The caliper is cleaned and brought to the reference temperature in the climate-controlled laboratory.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Visual and functional inspection:<\/strong> Condition of the measuring surfaces, smooth operation of the caliper, clamping action, zero point, and\u2014for digital devices\u2014the display.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Inspection of measuring surfaces:<\/strong> Flatness and parallelism of the outer measuring surfaces.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>External measurement:<\/strong> at multiple test points distributed across the entire measuring range, using traceable parallel gauges\u2014both near the jaw and at the tip of the jaw\u2014to detect tilt errors.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Internal measurement:<\/strong> using an adjusting ring or a combination of gauge blocks.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Depth and step measurement:<\/strong> using gauge blocks on a measuring plate.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Evaluation and Documentation:<\/strong> Measurement deviations are documented along with measurement uncertainty in the calibration certificate. Upon request, we can evaluate the results against your tolerance specifications or the manufacturer\u2019s error limits.<\/li>&#13;\n<\/ol>\r\n&#13;\n<p class=\"wp-block-paragraph\">All standards used are traceable to national standards. This way, you\u2019ll not only know whether your vernier caliper \u201cmeasures correctly,\u201d but also how accurately it actually measures. You can find more information on terms such as traceability and measurement uncertainty in our <a href=\"https:\/\/qmk-gmbh.de\/en\/qmk-calibration-lexicon\/\">QMK Calibration Glossary<\/a>.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Where is the vernier caliper used in practice?<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Anywhere where quick and reliable measurements are needed:<\/p>&#13;\n\r\n<ul class=\"wp-block-list\">&#13;\n<li><strong>In machining:<\/strong> on lathes, milling machines, and machining centers for self-inspection by operators<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>In incoming goods:<\/strong> for quick inspection of purchased parts<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>In assembly and maintenance:<\/strong> for on-site verification measurements<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>In quality assurance:<\/strong> as a test tool in inspection plans and during initial sample inspection<\/li>&#13;\n<\/ul>\r\n&#13;\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"673\" class=\"wp-image-3975\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-arbeitsplatz-kalibrierlabor-1024x673.jpg\" alt=\"Digital caliper with test equipment identification at the workplace\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-arbeitsplatz-kalibrierlabor-1024x673.jpg 1024w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-arbeitsplatz-kalibrierlabor-300x197.jpg 300w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-arbeitsplatz-kalibrierlabor-768x505.jpg 768w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-arbeitsplatz-kalibrierlabor.jpg 1408w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">Always within easy reach in everyday use\u2014and clearly tracked in the test equipment management system with a unique test equipment number.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">In many companies, the vernier caliper is the most common measuring instrument of all\u2014and thus a key component of any measuring instrument control program in accordance with ISO 9001 or IATF 16949.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Frequently Asked Questions About Calibrating Vernier Calipers<\/h2>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">How often should a vernier caliper be calibrated?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">There is no fixed, legally mandated interval. A 12-month interval is often used as a starting point. The frequency of use, environmental conditions, and the results of previous calibrations are the deciding factors. A vernier caliper used daily on a machine requires a shorter calibration interval than one stored in a metrology lab.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">Isn\u2019t it enough to check the caliper yourself using a master gauge?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">A spot check using a master gauge is a good idea and can prevent some unpleasant surprises. However, it does not replace a full calibration across the entire measurement range, including internal and depth measurements, inspection of the measuring surfaces, and documented measurement uncertainty.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">What happens if my vernier caliper is out of tolerance?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">We\u2019ll let you know and discuss together whether an adjustment or repair is worthwhile or if the device should be replaced. Important for your quality management: If a reading is outside the tolerance, you should check which measurements have been taken with the device since the last calibration.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">How do I send my calipers to QMK?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">You can send your measuring equipment by mail, drop it off in person, or use our <a href=\"https:\/\/qmk-gmbh.de\/en\/pick-up-and-delivery-service\/\">pickup and delivery service<\/a>.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Have Your Calipers Calibrated at QMK<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">As a DAkkS-accredited calibration laboratory (D-K-20571-01-00) based in Offenburg, we calibrate vernier calipers of all types and from all manufacturers\u2014quickly, traceably, and with clearly documented results. Would you like to have your calipers calibrated, or do you have questions about the appropriate calibration interval? Feel free to contact us.<\/p>&#13;\n\n<p class=\"wp-block-paragraph\"><strong>Next in the #100MeasuringInstruments series:<\/strong> No. 2 \u2013 <a href=\"https:\/\/qmk-gmbh.de\/en\/calibrating-a-limit-gauge-pass-and-fail-sides-wear-and-practical-application-100-measuring-equipment-no-2\/\">The Limit Gauge<\/a> \u00b7 No. 3 \u2013 <a href=\"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/\">The Micrometer<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Calibrating Vernier Calipers\u2014the Right Way: We explain their design and types, common sources of error, the calibration procedure according to VDI\/VDE\/DGQ 2618, and the appropriate calibration interval. Kickoff of our #100MeasuringInstruments series.<\/p>\n","protected":false},"author":2,"featured_media":3974,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[38],"tags":[],"class_list":["post-3980","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qmk-news-en","wpbf-post"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Calibrating Calipers \u2013 Procedure, Standards, and Frequency | QMK GmbH<\/title>\n<meta name=\"description\" content=\"Calibrating Vernier Calipers: Procedure according to VDI\/VDE\/DGQ 2618, Part 9.1; typical sources of error; calibration intervals; and practical tips from the QMK GmbH calibration laboratory in Offenburg.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Calibrating Calipers \u2013 Procedure, Standards, and Frequency | QMK GmbH\" \/>\n<meta property=\"og:description\" content=\"Calibrating Vernier Calipers: Procedure according to VDI\/VDE\/DGQ 2618, Part 9.1; typical sources of error; calibration intervals; and practical tips from the QMK GmbH calibration laboratory in Offenburg.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/\" \/>\n<meta property=\"og:site_name\" content=\"QMK GmbH\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-01T09:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-24T17:05:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1383\" \/>\n\t<meta property=\"og:image:height\" content=\"892\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Falko Krei\u00dfig\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Falko Krei\u00dfig\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/\"},\"author\":{\"name\":\"Falko Krei\u00dfig\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/person\\\/5e751ada4bb0092cb9d6c78c2310ba07\"},\"headline\":\"Calibrating Vernier Calipers: Setup, Procedure, and Practical Application | #100 Measuring Instruments No. 1\",\"datePublished\":\"2026-09-01T09:00:00+00:00\",\"dateModified\":\"2026-11-24T17:05:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/\"},\"wordCount\":1134,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/messschieber-kalibrieren-qmk.jpg\",\"articleSection\":[\"QMK News\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/\",\"name\":\"Calibrating Calipers \u2013 Procedure, Standards, and Frequency | QMK GmbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/messschieber-kalibrieren-qmk.jpg\",\"datePublished\":\"2026-09-01T09:00:00+00:00\",\"dateModified\":\"2026-11-24T17:05:10+00:00\",\"description\":\"Calibrating Vernier Calipers: Procedure according to VDI\\\/VDE\\\/DGQ 2618, Part 9.1; typical sources of error; calibration intervals; and practical tips from the QMK GmbH calibration laboratory in Offenburg.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/messschieber-kalibrieren-qmk.jpg\",\"contentUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/messschieber-kalibrieren-qmk.jpg\",\"width\":1383,\"height\":892},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/home-page\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Calibrating Vernier Calipers: Setup, Procedure, and Practical Application | #100 Measuring Instruments No. 1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/\",\"name\":\"QMK GmbH\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\",\"name\":\"QMK GmbH\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/QMK_Logo_Transparent.png\",\"contentUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/QMK_Logo_Transparent.png\",\"width\":296,\"height\":89,\"caption\":\"QMK GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/person\\\/5e751ada4bb0092cb9d6c78c2310ba07\",\"name\":\"Falko Krei\u00dfig\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"caption\":\"Falko Krei\u00dfig\"},\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/author\\\/falko\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Calibrating Calipers \u2013 Procedure, Standards, and Frequency | QMK GmbH","description":"Calibrating Vernier Calipers: Procedure according to VDI\/VDE\/DGQ 2618, Part 9.1; typical sources of error; calibration intervals; and practical tips from the QMK GmbH calibration laboratory in Offenburg.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/","og_locale":"en_US","og_type":"article","og_title":"Calibrating Calipers \u2013 Procedure, Standards, and Frequency | QMK GmbH","og_description":"Calibrating Vernier Calipers: Procedure according to VDI\/VDE\/DGQ 2618, Part 9.1; typical sources of error; calibration intervals; and practical tips from the QMK GmbH calibration laboratory in Offenburg.","og_url":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/","og_site_name":"QMK GmbH","article_published_time":"2026-09-01T09:00:00+00:00","article_modified_time":"2026-11-24T17:05:10+00:00","og_image":[{"width":1383,"height":892,"url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk.jpg","type":"image\/jpeg"}],"author":"Falko Krei\u00dfig","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Falko Krei\u00dfig","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/#article","isPartOf":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/"},"author":{"name":"Falko Krei\u00dfig","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/person\/5e751ada4bb0092cb9d6c78c2310ba07"},"headline":"Calibrating Vernier Calipers: Setup, Procedure, and Practical Application | #100 Measuring Instruments No. 1","datePublished":"2026-09-01T09:00:00+00:00","dateModified":"2026-11-24T17:05:10+00:00","mainEntityOfPage":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/"},"wordCount":1134,"commentCount":0,"publisher":{"@id":"https:\/\/qmk-gmbh.de\/en\/#organization"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/#primaryimage"},"thumbnailUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk.jpg","articleSection":["QMK News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/","url":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/","name":"Calibrating Calipers \u2013 Procedure, Standards, and Frequency | QMK GmbH","isPartOf":{"@id":"https:\/\/qmk-gmbh.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/#primaryimage"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/#primaryimage"},"thumbnailUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk.jpg","datePublished":"2026-09-01T09:00:00+00:00","dateModified":"2026-11-24T17:05:10+00:00","description":"Calibrating Vernier Calipers: Procedure according to VDI\/VDE\/DGQ 2618, Part 9.1; typical sources of error; calibration intervals; and practical tips from the QMK GmbH calibration laboratory in Offenburg.","breadcrumb":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/#primaryimage","url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk.jpg","contentUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk.jpg","width":1383,"height":892},{"@type":"BreadcrumbList","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/qmk-gmbh.de\/en\/home-page\/"},{"@type":"ListItem","position":2,"name":"Calibrating Vernier Calipers: Setup, Procedure, and Practical Application | #100 Measuring Instruments No. 1"}]},{"@type":"WebSite","@id":"https:\/\/qmk-gmbh.de\/en\/#website","url":"https:\/\/qmk-gmbh.de\/en\/","name":"QMK GmbH","description":"","publisher":{"@id":"https:\/\/qmk-gmbh.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/qmk-gmbh.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/qmk-gmbh.de\/en\/#organization","name":"QMK GmbH","url":"https:\/\/qmk-gmbh.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2022\/09\/QMK_Logo_Transparent.png","contentUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2022\/09\/QMK_Logo_Transparent.png","width":296,"height":89,"caption":"QMK GmbH"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/person\/5e751ada4bb0092cb9d6c78c2310ba07","name":"Falko Krei\u00dfig","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","caption":"Falko Krei\u00dfig"},"url":"https:\/\/qmk-gmbh.de\/en\/author\/falko\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/messschieber-kalibrieren-qmk.jpg","_links":{"self":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/3980","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/comments?post=3980"}],"version-history":[{"count":5,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/3980\/revisions"}],"predecessor-version":[{"id":4006,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/3980\/revisions\/4006"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/media\/3974"}],"wp:attachment":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/media?parent=3980"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/categories?post=3980"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/tags?post=3980"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}