{"id":3999,"date":"2026-09-15T09:00:00","date_gmt":"2026-09-15T09:00:00","guid":{"rendered":"https:\/\/qmk-gmbh.de\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/"},"modified":"2026-11-24T17:01:59","modified_gmt":"2026-11-24T17:01:59","slug":"calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3","status":"publish","type":"post","link":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/","title":{"rendered":"Calibrating a Dial Gauge: Body Heat, Measuring Force, and Flat Glass | #100 Measuring Instruments No. 3"},"content":{"rendered":"&#13;\n<p class=\"wp-block-paragraph\"><em>In our <strong>#100Messmittel<\/strong> series, we\u2019re showcasing 100 measuring and testing devices that we calibrate every day at QMK. So far, we\u2019ve covered the <a href=\"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/\">vernier caliper<\/a> and the <a href=\"https:\/\/qmk-gmbh.de\/en\/calibrating-a-limit-gauge-pass-and-fail-sides-wear-and-practical-application-100-measuring-equipment-no-2\/\">limit plug<\/a>. Today, we\u2019re taking it a step further in terms of precision.<\/em><\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">\ud83d\udd25 With this measuring instrument, the heat from your own hand can skew the result.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">No joke: A steel part that you hold in your hand for too long expands. With a length of 100 mm and a temperature difference of just a few degrees, we\u2019re talking about several micrometers. That might not sound like much\u2014but it\u2019s exactly the range in which this device operates.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Measuring instrument No. 3 in our series: the <strong>micrometer<\/strong>.<\/p>&#13;\n&#13;\n<figure class=\"wp-block-image aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"610\" height=\"925\" class=\"wp-image-3990\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-kalibrieren-qmk.jpg\" alt=\"An employee wearing a QMK polo shirt holds a micrometer at his workstation in the calibration lab\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-kalibrieren-qmk.jpg 610w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-kalibrieren-qmk-198x300.jpg 198w\" sizes=\"(max-width: 610px) 100vw, 610px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">The micrometer \u2013 one of the most frequently calibrated measuring instruments at our facility.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">What is a micrometer?<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Where the vernier caliper stops at tenths of a millimeter, the micrometer begins. Thanks to a precise measuring spindle with a defined thread, it provides resolution in the micrometer range\u2014which is why almost everyone calls it a \u201cmicrometer.\u201d It is the instrument of choice for critical dimensions: shafts, fits, and sealing surfaces.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">The principle is simple and ingenious: One revolution of the measuring spindle moves it by the thread pitch\u20140.5 mm on most devices. The scale drum divides this revolution into 50 divisions\u2014equaling 0.01 mm per division. Digital micrometers usually have a resolution of as fine as 0.001 mm.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">Overview of the Design<\/h3>&#13;\n\r\n<ul class=\"wp-block-list\">&#13;\n<li><strong>Bracket:<\/strong> supports the anvil and measuring spindle. It is often fitted with insulating plates\u2014precisely because of the heat from the hands.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Anvil and measuring spindle:<\/strong> feature the measuring surfaces, usually tipped with carbide to minimize wear.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Scale sleeve and scale drum<\/strong> or digital display.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Ratchet or spring-loaded ratchet:<\/strong> limits the measuring force so that each measurement is performed with the same force.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Locking mechanism:<\/strong> secures the spindle, e.g., for serial measurements.<\/li>&#13;\n<\/ul>\r\n&#13;\n<p class=\"wp-block-paragraph\">Clamp micrometers are available in measuring ranges of 25 mm each (0\u201325 mm, 25\u201350 mm, 50\u201375 mm, etc.). For larger ranges, an adjustment gauge is included to set the zero point or starting value.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Precision Comes at a Price: The Factors That Affect It<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">The measuring force, the cleanliness of the measuring surfaces, the temperature of the component, the temperature of the measuring instrument\u2014at this level of resolution, everything becomes a influencing factor that you could safely ignore when using a vernier caliper.<\/p>&#13;\n\r\n<ul class=\"wp-block-list\">&#13;\n<li><strong>Temperature:<\/strong> Steel expands by about 11.5 \u00b5m per meter per Kelvin. A 100-mm part that warms up by 3 \u00b0C in your hand is therefore already a good 3 \u00b5m longer. The reference temperature for length measurements is 20 \u00b0C.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Measuring force:<\/strong> A device tightened too tightly will systematically measure too low. Therefore, always measure using the ratchet; never \u201cpush down\u201d on the drum.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Cleanliness:<\/strong> Even a thin film of oil or a single speck of dust on the measuring surfaces can skew the result by several micrometers.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Handling:<\/strong> Hold the micrometer by the insulated handle and allow it to acclimate for a sufficient amount of time before taking a measurement.<\/li>&#13;\n<\/ul>\r\n&#13;\n<h2 class=\"wp-block-heading\">How do we calibrate a micrometer?<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">We check the display accuracy across the entire measuring range against traceable reference gauges. To do this, we check the flatness and parallelism of the measuring surfaces\u2014we examine these using a magnifying glass, where deviations become visible as interference fringes. And we check the measuring force, because a device that is tightened too tightly will systematically measure too low.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">The procedure in detail:<\/p>&#13;\n\r\n<ol class=\"wp-block-list\">&#13;\n<li><strong>Cleaning and Temperature Control:<\/strong> The device and standards are brought to 20 \u00b0C in the climate-controlled laboratory.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Visual and functional inspection:<\/strong> Smooth operation of the spindle, function of the ratchet and locking mechanism, condition of the measuring surfaces, zero point.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Flatness of the measuring surfaces:<\/strong> An optical flat glass plate is placed on the measuring surface. The resulting interference fringes indicate deviations from the plane\u2014each fringe corresponds to only about 0.3 \u00b5m.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Parallelism of the measuring surfaces:<\/strong> Using plane-parallel glass plates of varying thicknesses, so that the spindle is tested in different rotational positions.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Display accuracy:<\/strong> Using gauge blocks at test points distributed across the measuring range and covering various spindle positions\u2014this also reveals periodic pitch errors in the measuring spindle.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Measured force:<\/strong> Check whether the ratchet triggers within the permissible range.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Setpoint:<\/strong> If available, the corresponding setpoint is also calibrated.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Documentation:<\/strong> Measurement deviations with measurement uncertainty are recorded in the calibration certificate; a statement of conformity is provided upon request.<\/li>&#13;\n<\/ol>\r\n&#13;\n<p class=\"wp-block-paragraph\">The basis for this is the product standard DIN EN ISO 3611 for micrometers. You can find more information on traceability and measurement uncertainty in <a href=\"https:\/\/qmk-gmbh.de\/en\/qmk-calibration-lexicon\/\">the QMK Calibration Glossary<\/a>.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Where is the micrometer used in practice?<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Anywhere where tolerances are tighter than a few hundredths: shaft diameters, bearing seats, sealing surfaces. In quality assurance, it\u2019s often the final word before approval\u2014whatever it says goes, or it doesn\u2019t.<\/p>&#13;\n&#13;\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"624\" height=\"938\" class=\"wp-image-3992\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-messen-schulung.jpg\" alt=\"Measuring Correctly with a Vernier Caliper: On-the-Job Training at the QMK Calibration Laboratory\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-messen-schulung.jpg 624w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-messen-schulung-200x300.jpg 200w\" sizes=\"(max-width: 624px) 100vw, 624px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">Accurate measurement takes practice\u2014especially in the micrometer range.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">A device capable of measuring in micrometers must itself be accurate down to the micrometer level. Otherwise, you\u2019ll be measuring very precisely\u2014but incorrectly. At QMK, we\u2019ve already calibrated over 12,500 micrometers.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">And because even the best measuring instrument is only as good as the hand that operates it: In our <a href=\"https:\/\/qmk-gmbh.de\/en\/trainings-seminars\/\">training courses and seminars<\/a>, we show you what really matters when it comes to measuring.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Frequently Asked Questions About Calibrating Micrometers<\/h2>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">How often should a micrometer be calibrated?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">There is no legally mandated interval. It is common to start with a 12-month interval, which is then adjusted based on usage, the environment, and previous calibration results. Equipment used daily in manufacturing typically requires shorter intervals.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">Is it sufficient to check the zero point yourself?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Checking the zero point before measuring is important, but it only provides information about a single point. This method does not detect lead errors in the spindle, measuring surfaces that are no longer flat or parallel, or an incorrect measuring force.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">Does the reference dimension need to be calibrated as well?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Yes. For micrometers with a range of 25 mm or more, the starting value is set using the calibration gauge. If the calibration gauge is incorrect, every measurement will be off by the same amount.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">How do I send my micrometers to QMK?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">By mail, in person, or via our <a href=\"https:\/\/qmk-gmbh.de\/en\/pick-up-and-delivery-service\/\">pickup and delivery service<\/a>.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Have your micrometers calibrated at QMK<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">As a DAkkS-accredited calibration laboratory (D-K-20571-01-00) based in Offenburg, we calibrate micrometers of all types\u2014analog and digital, with and without a set gauge. Feel free to contact us.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\"><strong>So far in the #100MeasuringInstruments series:<\/strong> No. 1 \u2013 <a href=\"https:\/\/qmk-gmbh.de\/en\/calibrating-vernier-calipers-setup-procedure-and-practical-application-100-measuring-instruments-no-1\/\">The Vernier Caliper<\/a> \u00b7 No. 2 \u2013 <a href=\"https:\/\/qmk-gmbh.de\/en\/calibrating-a-limit-gauge-pass-and-fail-sides-wear-and-practical-application-100-measuring-equipment-no-2\/\">The Gauge Pin<\/a><\/p>&#13;\n","protected":false},"excerpt":{"rendered":"<p>With a micrometer, even the heat from your hand can skew the results. We\u2019ll explain what a \u201cmicrometer\u201d can do, which factors in the \u00b5m range matter, and how we calibrate micrometers using gauge blocks and flat glass.<\/p>\n","protected":false},"author":2,"featured_media":3991,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[38],"tags":[],"class_list":["post-3999","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qmk-news-en","wpbf-post"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Calibrating a Dial Indicator \u2013 Procedure, Flat Glass, and Measuring Force | QMK GmbH<\/title>\n<meta name=\"description\" content=\"Having a dial indicator calibrated: Effects of temperature and measuring force, testing with gauge blocks and flat glass, calibration intervals, and practical tips from the QMK GmbH calibration laboratory.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Calibrating a Dial Indicator \u2013 Procedure, Flat Glass, and Measuring Force | QMK GmbH\" \/>\n<meta property=\"og:description\" content=\"Having a dial indicator calibrated: Effects of temperature and measuring force, testing with gauge blocks and flat glass, calibration intervals, and practical tips from the QMK GmbH calibration laboratory.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/\" \/>\n<meta property=\"og:site_name\" content=\"QMK GmbH\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-15T09:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-24T17:01:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-kalibrieren-qmk.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"610\" \/>\n\t<meta property=\"og:image:height\" content=\"925\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Falko Krei\u00dfig\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Falko Krei\u00dfig\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/\"},\"author\":{\"name\":\"Falko Krei\u00dfig\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/person\\\/5e751ada4bb0092cb9d6c78c2310ba07\"},\"headline\":\"Calibrating a Dial Gauge: Body Heat, Measuring Force, and Flat Glass | #100 Measuring Instruments No. 3\",\"datePublished\":\"2026-09-15T09:00:00+00:00\",\"dateModified\":\"2026-11-24T17:01:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/\"},\"wordCount\":1099,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/buegelmessschraube-kalibrieren-qmk.jpg\",\"articleSection\":[\"QMK News\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/\",\"name\":\"Calibrating a Dial Indicator \u2013 Procedure, Flat Glass, and Measuring Force | QMK GmbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/buegelmessschraube-kalibrieren-qmk.jpg\",\"datePublished\":\"2026-09-15T09:00:00+00:00\",\"dateModified\":\"2026-11-24T17:01:59+00:00\",\"description\":\"Having a dial indicator calibrated: Effects of temperature and measuring force, testing with gauge blocks and flat glass, calibration intervals, and practical tips from the QMK GmbH calibration laboratory.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/buegelmessschraube-kalibrieren-qmk.jpg\",\"contentUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/buegelmessschraube-kalibrieren-qmk.jpg\",\"width\":610,\"height\":925},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/home-page\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Calibrating a Dial Gauge: Body Heat, Measuring Force, and Flat Glass | #100 Measuring Instruments No. 3\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/\",\"name\":\"QMK GmbH\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\",\"name\":\"QMK GmbH\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/QMK_Logo_Transparent.png\",\"contentUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/QMK_Logo_Transparent.png\",\"width\":296,\"height\":89,\"caption\":\"QMK GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/person\\\/5e751ada4bb0092cb9d6c78c2310ba07\",\"name\":\"Falko Krei\u00dfig\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"caption\":\"Falko Krei\u00dfig\"},\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/author\\\/falko\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Calibrating a Dial Indicator \u2013 Procedure, Flat Glass, and Measuring Force | QMK GmbH","description":"Having a dial indicator calibrated: Effects of temperature and measuring force, testing with gauge blocks and flat glass, calibration intervals, and practical tips from the QMK GmbH calibration laboratory.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/","og_locale":"en_US","og_type":"article","og_title":"Calibrating a Dial Indicator \u2013 Procedure, Flat Glass, and Measuring Force | QMK GmbH","og_description":"Having a dial indicator calibrated: Effects of temperature and measuring force, testing with gauge blocks and flat glass, calibration intervals, and practical tips from the QMK GmbH calibration laboratory.","og_url":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/","og_site_name":"QMK GmbH","article_published_time":"2026-09-15T09:00:00+00:00","article_modified_time":"2026-11-24T17:01:59+00:00","og_image":[{"width":610,"height":925,"url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-kalibrieren-qmk.jpg","type":"image\/jpeg"}],"author":"Falko Krei\u00dfig","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Falko Krei\u00dfig","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/#article","isPartOf":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/"},"author":{"name":"Falko Krei\u00dfig","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/person\/5e751ada4bb0092cb9d6c78c2310ba07"},"headline":"Calibrating a Dial Gauge: Body Heat, Measuring Force, and Flat Glass | #100 Measuring Instruments No. 3","datePublished":"2026-09-15T09:00:00+00:00","dateModified":"2026-11-24T17:01:59+00:00","mainEntityOfPage":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/"},"wordCount":1099,"commentCount":0,"publisher":{"@id":"https:\/\/qmk-gmbh.de\/en\/#organization"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/#primaryimage"},"thumbnailUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-kalibrieren-qmk.jpg","articleSection":["QMK News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/","url":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/","name":"Calibrating a Dial Indicator \u2013 Procedure, Flat Glass, and Measuring Force | QMK GmbH","isPartOf":{"@id":"https:\/\/qmk-gmbh.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/#primaryimage"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/#primaryimage"},"thumbnailUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-kalibrieren-qmk.jpg","datePublished":"2026-09-15T09:00:00+00:00","dateModified":"2026-11-24T17:01:59+00:00","description":"Having a dial indicator calibrated: Effects of temperature and measuring force, testing with gauge blocks and flat glass, calibration intervals, and practical tips from the QMK GmbH calibration laboratory.","breadcrumb":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/#primaryimage","url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-kalibrieren-qmk.jpg","contentUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-kalibrieren-qmk.jpg","width":610,"height":925},{"@type":"BreadcrumbList","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-dial-gauge-body-heat-measuring-force-and-flat-glass-100-measuring-instruments-no-3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/qmk-gmbh.de\/en\/home-page\/"},{"@type":"ListItem","position":2,"name":"Calibrating a Dial Gauge: Body Heat, Measuring Force, and Flat Glass | #100 Measuring Instruments No. 3"}]},{"@type":"WebSite","@id":"https:\/\/qmk-gmbh.de\/en\/#website","url":"https:\/\/qmk-gmbh.de\/en\/","name":"QMK GmbH","description":"","publisher":{"@id":"https:\/\/qmk-gmbh.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/qmk-gmbh.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/qmk-gmbh.de\/en\/#organization","name":"QMK GmbH","url":"https:\/\/qmk-gmbh.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2022\/09\/QMK_Logo_Transparent.png","contentUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2022\/09\/QMK_Logo_Transparent.png","width":296,"height":89,"caption":"QMK GmbH"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/person\/5e751ada4bb0092cb9d6c78c2310ba07","name":"Falko Krei\u00dfig","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","caption":"Falko Krei\u00dfig"},"url":"https:\/\/qmk-gmbh.de\/en\/author\/falko\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/buegelmessschraube-kalibrieren-qmk.jpg","_links":{"self":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/3999","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/comments?post=3999"}],"version-history":[{"count":1,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/3999\/revisions"}],"predecessor-version":[{"id":4000,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/3999\/revisions\/4000"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/media\/3991"}],"wp:attachment":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/media?parent=3999"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/categories?post=3999"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/tags?post=3999"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}