{"id":4039,"date":"2026-10-06T09:00:00","date_gmt":"2026-10-06T09:00:00","guid":{"rendered":"https:\/\/qmk-gmbh.de\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/"},"modified":"2026-11-25T10:41:20","modified_gmt":"2026-11-25T10:41:20","slug":"calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6","status":"publish","type":"post","link":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/","title":{"rendered":"Calibrating Pressure Gauges: Hysteresis, Accuracy Class, and Pressure Units | #100Measuring Instruments No. 6"},"content":{"rendered":"&#13;\n<p class=\"wp-block-paragraph\"><em>In our <strong>#100Messmittel<\/strong> series, we\u2019re showcasing 100 measuring and testing devices that we calibrate every day at QMK. After length, electrical parameters, and torque, today we\u2019re focusing on the fourth measurement parameter: pressure.<\/em><\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">\ud83d\udd34 A pressure gauge always shows you a pressure reading. The only question is whether it\u2019s the correct one.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">The needle stands firmly at \u201c6 bar\u201d\u2014and no one at the plant doubts it. But that\u2019s exactly the trap: a pressure gauge gradually loses its accuracy. You can\u2019t tell just by looking at it.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Measuring instrument No. 6 in our series: the <strong>pressure gauge<\/strong>.<\/p>&#13;\n&#13;\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"683\" class=\"wp-image-4029\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand-1024x683.jpg\" alt=\"Calibration on the pressure test bench using a digital reference pressure gauge in the QMK laboratory\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand-1024x683.jpg 1024w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand-300x200.jpg 300w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand-768x512.jpg 768w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand.jpg 1418w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">On the pressure test bench, the test specimen is compared to a feedback-controlled reference device.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">What is a pressure gauge?<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">The classic pressure gauge uses a Bourdon tube, also known as a Bourdon spring: A bent tube stretches slightly under pressure, and this movement drives the pointer via a pointer mechanism. Simple and robust\u2014but the tube spring ages, develops hysteresis, and eventually displays a different reading when pressure rises than when it falls.<\/p>&#13;\n&#13;\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"624\" height=\"949\" class=\"wp-image-4033\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/bourdonrohr-manometer-genauigkeitsklasse.jpg\" alt=\"Bourdon tube pressure gauge in accordance with EN 837-1, with a scale up to 100 bar and accuracy class 1.0\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/bourdonrohr-manometer-genauigkeitsklasse.jpg 624w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/bourdonrohr-manometer-genauigkeitsklasse-197x300.jpg 197w\" sizes=\"(max-width: 624px) 100vw, 624px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">Bourdon tube pressure gauges in accordance with EN 837-1\u2014the accuracy class is marked directly on the dial (\u201cCL 1.0\u201d).<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">What does the accuracy class mean?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">The dial of many pressure gauges displays a class, such as \u201cCL 1.0.\u201d This indicates the permissible deviation as a percentage of the measuring range. For a Class 1.0 pressure gauge with a measuring range of 0 to 100 bar, the reading may therefore deviate by up to 1 bar at any point on the scale\u2014at an operating pressure of 6 bar, that\u2019s already about 17% of the measured value. That\u2019s why it\u2019s a good idea to choose a measurement range so that the operating pressure isn\u2019t right at the bottom of the scale.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">How do we calibrate a pressure gauge?<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Compared to a traceable pressure standard, across multiple test points\u2014and deliberately in both directions: rising and falling. This is exactly how the hysteresis becomes apparent, which would be overlooked in a single measurement. The calibration certificate lists the actual deviation at each point, not just at the end of the scale.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">An overview of the procedure:<\/p>&#13;\n\r\n<ol class=\"wp-block-list\">&#13;\n<li><strong>Visual and functional inspection:<\/strong> Condition of the case, dial, connection threads, and pointer; zero point when the gauge is unpressurized.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Pre-loading:<\/strong> Before measurement, the pressure gauge is loaded multiple times up to the upper limit of the measurement range.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Ascending measurement series:<\/strong> Several test points across the entire measurement range are reached sequentially and compared with the reference value.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Descending measurement series:<\/strong> The same points in reverse order. The difference between the two series indicates the hysteresis.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Evaluation and Documentation:<\/strong> Deviation, hysteresis, and measurement uncertainty for each test point; upon request, with an assessment against the accuracy class.<\/li>&#13;\n<\/ol>\r\n&#13;\n<p class=\"wp-block-paragraph\">With mechanical pressure gauges, gently tap the housing before taking a reading. This reveals whether friction in the pointer mechanism is causing the pointer to \u201cstick.\u201d You can find more information on traceability and measurement uncertainty in <a href=\"https:\/\/qmk-gmbh.de\/en\/qmk-calibration-lexicon\/\">the QMK Calibration Glossary<\/a>.<\/p>&#13;\n&#13;\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"686\" class=\"wp-image-4031\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-druckmessgeraete-kalibrierung-1024x686.jpg\" alt=\"Analog pressure gauges and digital pressure transducers in a transport case prior to calibration\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-druckmessgeraete-kalibrierung-1024x686.jpg 1024w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-druckmessgeraete-kalibrierung-300x201.jpg 300w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-druckmessgeraete-kalibrierung-768x514.jpg 768w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-druckmessgeraete-kalibrierung.jpg 1410w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">Analog or digital: Every pressure gauge is tested against a traceable standard.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Where are pressure gauges used in practice?<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Anywhere pressure plays a role: on compressors and hydraulic systems, in process engineering, on test benches, and in leak testing. A pressure gauge that displays incorrect readings can render an entire system acceptance test or safety inspection invalid.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">Fun fact: bar, psi, kPa, mmHg\u2014the variety of units used for pressure<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Hardly any other physical quantity has as many units as pressure. Every day, we juggle between bar, psi, kPa, and even mmHg\u2014depending on the customer, industry, and country of origin of the device. And that\u2019s no small matter: 1 bar is roughly 14.5 psi. If you mix the two up, you\u2019re not just a little off\u2014you\u2019re off by a factor of 14. Keeping track of units accurately is part of our craft.<\/p>&#13;\n&#13;\n<figure class=\"wp-block-table\">&#13;\n<table>&#13;\n<thead>&#13;\n<tr>&#13;\n<th>Unit<\/th>&#13;\n<th>Equivalent to 1 bar<\/th>&#13;\n<th>Typical use<\/th>&#13;\n<\/tr>&#13;\n<\/thead>&#13;\n<tbody>&#13;\n<tr>&#13;\n<td>bar<\/td>&#13;\n<td>1 bar<\/td>&#13;\n<td>Industry and Technology in Europe<\/td>&#13;\n<\/tr>&#13;\n<tr>&#13;\n<td>kPa<\/td>&#13;\n<td>100 kPa<\/td>&#13;\n<td>SI units, standards, and science<\/td>&#13;\n<\/tr>&#13;\n<tr>&#13;\n<td>psi<\/td>&#13;\n<td>approx. 14.5 psi<\/td>&#13;\n<td>Devices from the U.S., tire pressure<\/td>&#13;\n<\/tr>&#13;\n<tr>&#13;\n<td>mmHg<\/td>&#13;\n<td>approx. 750 mmHg<\/td>&#13;\n<td>Medicine, vacuum technology<\/td>&#13;\n<\/tr>&#13;\n<\/tbody>&#13;\n<\/table>&#13;\n<\/figure>&#13;\n&#13;\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"627\" height=\"938\" class=\"wp-image-4035\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-digitale-druckmessgeraete-qmk.jpg\" alt=\"Top view of a box containing analog pressure gauges and digital pressure measuring devices for calibration\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-digitale-druckmessgeraete-qmk.jpg 627w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-digitale-druckmessgeraete-qmk-201x300.jpg 201w\" sizes=\"(max-width: 627px) 100vw, 627px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">We have already calibrated 2,258 pressure measuring devices\u2014ranging from analog pressure gauges to digital measuring instruments.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">A reading that looks convincing is by no means an accurate value. Only those who calibrate know the difference.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">By the way: Digital pressure transmitters that send their signal directly to the plant control system are a topic all their own\u2014we\u2019ll take a closer look at them in a later post.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Frequently Asked Questions About Calibrating Pressure Gauges<\/h2>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">How often should a pressure gauge be calibrated?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">There\u2019s no set interval. Twelve months is a common starting point. In cases of pressure spikes, vibrations, pulsating pressure, or aggressive media, a shorter interval may be advisable\u2014as well as after an overload or if the pointer no longer reads zero when the system is depressurized.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">What is hysteresis in a pressure gauge?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Hysteresis is the difference in the reading at the same pressure, depending on whether the pressure is approached from below (rising) or from above (falling). It results from the material properties of the spring and friction in the pointer mechanism\u2014and is only noticeable when measurements are taken in both directions.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">Do you also calibrate digital pressure gauges?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Yes\u2014from analog pressure gauges to digital handheld meters to pressure transducers. We\u2019ll be dedicating a separate article to the latter in this series.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">How do I get my pressure gauges to QMK?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">By mail, in person, or via our <a href=\"https:\/\/qmk-gmbh.de\/en\/pick-up-and-delivery-service\/\">pickup and delivery service<\/a>.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Have your pressure gauges calibrated at QMK<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">As a DAkkS-accredited calibration laboratory (D-K-20571-01-00) based in Offenburg, we calibrate pressure gauges and pressure measuring instruments\u2014both analog and digital\u2014using ascending and descending measurement ranges. Please feel free to contact us.<\/p>&#13;\n","protected":false},"excerpt":{"rendered":"<p>A pressure gauge always shows you a pressure reading\u2014the question is whether it\u2019s the right one. We\u2019ll explain how the Bourdon tube works, why we calibrate using both rising and falling scales, and why confusing bar and psi results in a 14-fold error.<\/p>\n","protected":false},"author":2,"featured_media":4030,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[38],"tags":[],"class_list":["post-4039","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qmk-news-en","wpbf-post"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Calibrating Pressure Gauges \u2013 Procedure, Hysteresis, and Accuracy Class | QMK GmbH<\/title>\n<meta name=\"description\" content=\"Pressure gauge calibration: Rising and falling pressure measurements against traceable pressure standards, hysteresis, accuracy classes according to EN 837-1, and pressure units\u2014from the QMK GmbH calibration laboratory.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Calibrating Pressure Gauges \u2013 Procedure, Hysteresis, and Accuracy Class | QMK GmbH\" \/>\n<meta property=\"og:description\" content=\"Pressure gauge calibration: Rising and falling pressure measurements against traceable pressure standards, hysteresis, accuracy classes according to EN 837-1, and pressure units\u2014from the QMK GmbH calibration laboratory.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/\" \/>\n<meta property=\"og:site_name\" content=\"QMK GmbH\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-06T09:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-25T10:41:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1418\" \/>\n\t<meta property=\"og:image:height\" content=\"946\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Falko Krei\u00dfig\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Falko Krei\u00dfig\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/\"},\"author\":{\"name\":\"Falko Krei\u00dfig\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/person\\\/5e751ada4bb0092cb9d6c78c2310ba07\"},\"headline\":\"Calibrating Pressure Gauges: Hysteresis, Accuracy Class, and Pressure Units | #100Measuring Instruments No. 6\",\"datePublished\":\"2026-10-06T09:00:00+00:00\",\"dateModified\":\"2026-11-25T10:41:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/\"},\"wordCount\":968,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/manometer-kalibrieren-druckpruefstand.jpg\",\"articleSection\":[\"QMK News\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/\",\"name\":\"Calibrating Pressure Gauges \u2013 Procedure, Hysteresis, and Accuracy Class | QMK GmbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/manometer-kalibrieren-druckpruefstand.jpg\",\"datePublished\":\"2026-10-06T09:00:00+00:00\",\"dateModified\":\"2026-11-25T10:41:20+00:00\",\"description\":\"Pressure gauge calibration: Rising and falling pressure measurements against traceable pressure standards, hysteresis, accuracy classes according to EN 837-1, and pressure units\u2014from the QMK GmbH calibration laboratory.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/#primaryimage\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/manometer-kalibrieren-druckpruefstand.jpg\",\"contentUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/manometer-kalibrieren-druckpruefstand.jpg\",\"width\":1418,\"height\":946},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/home-page\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Calibrating Pressure Gauges: Hysteresis, Accuracy Class, and Pressure Units | #100Measuring Instruments No. 6\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/\",\"name\":\"QMK GmbH\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\",\"name\":\"QMK GmbH\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/QMK_Logo_Transparent.png\",\"contentUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/QMK_Logo_Transparent.png\",\"width\":296,\"height\":89,\"caption\":\"QMK GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/person\\\/5e751ada4bb0092cb9d6c78c2310ba07\",\"name\":\"Falko Krei\u00dfig\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"caption\":\"Falko Krei\u00dfig\"},\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/author\\\/falko\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Calibrating Pressure Gauges \u2013 Procedure, Hysteresis, and Accuracy Class | QMK GmbH","description":"Pressure gauge calibration: Rising and falling pressure measurements against traceable pressure standards, hysteresis, accuracy classes according to EN 837-1, and pressure units\u2014from the QMK GmbH calibration laboratory.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/","og_locale":"en_US","og_type":"article","og_title":"Calibrating Pressure Gauges \u2013 Procedure, Hysteresis, and Accuracy Class | QMK GmbH","og_description":"Pressure gauge calibration: Rising and falling pressure measurements against traceable pressure standards, hysteresis, accuracy classes according to EN 837-1, and pressure units\u2014from the QMK GmbH calibration laboratory.","og_url":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/","og_site_name":"QMK GmbH","article_published_time":"2026-10-06T09:00:00+00:00","article_modified_time":"2026-11-25T10:41:20+00:00","og_image":[{"width":1418,"height":946,"url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand.jpg","type":"image\/jpeg"}],"author":"Falko Krei\u00dfig","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Falko Krei\u00dfig","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/#article","isPartOf":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/"},"author":{"name":"Falko Krei\u00dfig","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/person\/5e751ada4bb0092cb9d6c78c2310ba07"},"headline":"Calibrating Pressure Gauges: Hysteresis, Accuracy Class, and Pressure Units | #100Measuring Instruments No. 6","datePublished":"2026-10-06T09:00:00+00:00","dateModified":"2026-11-25T10:41:20+00:00","mainEntityOfPage":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/"},"wordCount":968,"commentCount":0,"publisher":{"@id":"https:\/\/qmk-gmbh.de\/en\/#organization"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/#primaryimage"},"thumbnailUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand.jpg","articleSection":["QMK News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/","url":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/","name":"Calibrating Pressure Gauges \u2013 Procedure, Hysteresis, and Accuracy Class | QMK GmbH","isPartOf":{"@id":"https:\/\/qmk-gmbh.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/#primaryimage"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/#primaryimage"},"thumbnailUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand.jpg","datePublished":"2026-10-06T09:00:00+00:00","dateModified":"2026-11-25T10:41:20+00:00","description":"Pressure gauge calibration: Rising and falling pressure measurements against traceable pressure standards, hysteresis, accuracy classes according to EN 837-1, and pressure units\u2014from the QMK GmbH calibration laboratory.","breadcrumb":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/#primaryimage","url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand.jpg","contentUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand.jpg","width":1418,"height":946},{"@type":"BreadcrumbList","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-pressure-gauges-hysteresis-accuracy-class-and-pressure-units-100measuring-instruments-no-6\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/qmk-gmbh.de\/en\/home-page\/"},{"@type":"ListItem","position":2,"name":"Calibrating Pressure Gauges: Hysteresis, Accuracy Class, and Pressure Units | #100Measuring Instruments No. 6"}]},{"@type":"WebSite","@id":"https:\/\/qmk-gmbh.de\/en\/#website","url":"https:\/\/qmk-gmbh.de\/en\/","name":"QMK GmbH","description":"","publisher":{"@id":"https:\/\/qmk-gmbh.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/qmk-gmbh.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/qmk-gmbh.de\/en\/#organization","name":"QMK GmbH","url":"https:\/\/qmk-gmbh.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2022\/09\/QMK_Logo_Transparent.png","contentUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2022\/09\/QMK_Logo_Transparent.png","width":296,"height":89,"caption":"QMK GmbH"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/person\/5e751ada4bb0092cb9d6c78c2310ba07","name":"Falko Krei\u00dfig","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","caption":"Falko Krei\u00dfig"},"url":"https:\/\/qmk-gmbh.de\/en\/author\/falko\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/manometer-kalibrieren-druckpruefstand.jpg","_links":{"self":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/4039","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/comments?post=4039"}],"version-history":[{"count":1,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/4039\/revisions"}],"predecessor-version":[{"id":4040,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/4039\/revisions\/4040"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/media\/4030"}],"wp:attachment":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/media?parent=4039"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/categories?post=4039"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/tags?post=4039"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}