{"id":4042,"date":"2026-09-29T09:00:00","date_gmt":"2026-09-29T09:00:00","guid":{"rendered":"https:\/\/qmk-gmbh.de\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/"},"modified":"2026-11-25T10:42:18","modified_gmt":"2026-11-25T10:42:18","slug":"calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5","status":"publish","type":"post","link":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/","title":{"rendered":"Calibrating a Torque Wrench: When the \u201cClick\u201d Is Off | #100Measuring Instruments No. 5"},"content":{"rendered":"&#13;\n<p class=\"wp-block-paragraph\"><em>In our <strong>#100Messmittel<\/strong> series, we\u2019re showcasing 100 measuring and testing devices that we calibrate every day at QMK. Following length and electrical properties, today we\u2019re focusing on the third measurement parameter: torque.<\/em><\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">\ud83d\udd27 With a torque wrench, an error in either direction is dangerous. Too little\u2014and the connection comes loose. Too much\u2014and the screw shears.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">The tricky part: You hear the \u201cclick\u201d and trust it. But that very click is the point of wear.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Measuring instrument No. 5 in our series: the <strong>torque wrench<\/strong>.<\/p>&#13;\n&#13;\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"684\" class=\"wp-image-4020\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand-1024x684.jpg\" alt=\"A torque wrench is calibrated on a torque test bench using software analysis\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand-1024x684.jpg 1024w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand-300x200.jpg 300w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand-768x513.jpg 768w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand.jpg 1280w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">Torque wrenches put to the test: Here\u2019s where we find out what that \u201cclick\u201d is really worth.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">What is a torque wrench?<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">A torque wrench applies a defined tightening torque\u2014measured in newton-meters (Nm). In the classic click-type design, a spring mechanism triggers a noticeable click when the set value is reached. And that\u2019s where the weakness lies: springs and tension elements wear out. A wrench that sits coiled in a toolbox for years and triggers daily will slowly lose its calibration. The set torque and the actual torque drift apart\u2014without you even noticing.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">Indicating or snapping: the two basic types<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">DIN EN ISO 6789 distinguishes between two types:<\/p>&#13;\n\r\n<ul class=\"wp-block-list\">&#13;\n<li><strong>Type I \u2013 indicating torque wrenches:<\/strong> They display the applied torque, e.g., via a scale, a dial gauge, or a display.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Type II \u2013 triggering torque wrenches:<\/strong> They trigger when the set value is reached\u2014usually with the characteristic \u201cclick.\u201d This is the type most commonly found in workshops.<\/li>&#13;\n<\/ul>\r\n&#13;\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"627\" height=\"946\" class=\"wp-image-4026\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/ausloesender-drehmomentschluessel-klick.jpg\" alt=\"Reversible torque wrench with reversible ratchet in a case\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/ausloesender-drehmomentschluessel-klick.jpg 627w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/ausloesender-drehmomentschluessel-klick-199x300.jpg 199w\" sizes=\"(max-width: 627px) 100vw, 627px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">A workshop classic: the ratchet torque wrench.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">How do we calibrate a torque wrench?<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">On a torque test bench against a traceable reference transducer. We apply several setpoints across the measurement range and record the actual deviation at each point\u2014in accordance with the standard and with defined repetition, since operator variation also affects torque readings. The calibration certificate then states in black and white exactly what the wrench does at \u201c50 Nm.\u201d<\/p>&#13;\n&#13;\n<figure class=\"wp-block-image aligncenter size-full\"><img decoding=\"async\" width=\"989\" height=\"660\" class=\"wp-image-4022\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-referenzaufnehmer.jpg\" alt=\"The torque wrench is placed on a reference torque transducer for calibration.\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-referenzaufnehmer.jpg 989w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-referenzaufnehmer-300x200.jpg 300w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-referenzaufnehmer-768x513.jpg 768w\" sizes=\"(max-width: 989px) 100vw, 989px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">The reference transducer measures the actual torque present at the moment of release.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">An overview of the procedure:<\/p>&#13;\n\r\n<ol class=\"wp-block-list\">&#13;\n<li><strong>Visual and functional inspection:<\/strong> Condition of the ratchet, square drive, scale, and adjustment mechanism.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Preload:<\/strong> Before the actual measurement, the wrench is loaded several times to its maximum value so that the mechanism \u201csettles in.\u201d<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Measurement at multiple test points:<\/strong> typically at the lower, middle, and upper ranges of the scale, with multiple repetitions at each point.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Evaluation:<\/strong> Deviation from the set value and measurement uncertainty for each test point; upon request, with an assessment against the permissible limit values specified in the standard.<\/li>&#13;\n\r\n\r\n&#13;\n<li><strong>Documentation<\/strong> in the calibration certificate.<\/li>&#13;\n<\/ol>\r\n&#13;\n<p class=\"wp-block-paragraph\">The basis is <strong>DIN EN ISO 6789<\/strong>: Part 1 specifies the requirements for torque screwdrivers, while Part 2 describes calibration and the determination of measurement uncertainty. You can find more information on traceability and measurement uncertainty in <a href=\"https:\/\/qmk-gmbh.de\/en\/qmk-calibration-lexicon\/\">the QMK Calibration Glossary<\/a>.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Where are torque wrenches used in practice?<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Anywhere a bolted joint is safety-critical: in automotive workshops for wheel nuts and drivetrain components, in assembly for flanges, bearing caps, and housings, and on equipment for safety-critical bolted joints. In quality assurance and service, the specified tightening torque is often a parameter that must be documented. \u201cTight by hand plus a feel for it\u201d simply isn\u2019t enough.<\/p>&#13;\n&#13;\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"684\" class=\"wp-image-4024\" src=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrierung-qmk-1024x684.jpg\" alt=\"Various torque wrenches in a transport case prior to calibration\" srcset=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrierung-qmk-1024x684.jpg 1024w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrierung-qmk-300x200.jpg 300w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrierung-qmk-768x513.jpg 768w, https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrierung-qmk.jpg 1413w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/>&#13;\n<figcaption class=\"wp-element-caption\">We have already calibrated 8,694 different torque screwdrivers.<\/figcaption>&#13;\n<\/figure>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">Fun Fact: You\u2019ll reach 5,000 activations faster than you think<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">DIN EN ISO 6789 recommends recalibration after 12 months or 5,000 actuations\u2014whichever comes first. And that happens faster than you think: With five wheel bolts per vehicle, 5,000 load cycles are reached after just 250 vehicles. A busy auto repair shop will therefore often hit that limit long before the 12 months are up.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">Tip: Release the tension on the ratchet wrench after use<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Trigger-type torque wrenches should be reset to the lowest scale value after use\u2014but not below zero. This prevents the spring from being stored under constant tension and slows down spring fatigue. Otherwise, a wrench that sits in a case set to 200 Nm for months on end will gradually lose its accuracy.<\/p>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">A tool designed to ensure safety must know its own force. Otherwise, you\u2019ll tighten with great confidence\u2014but with the wrong torque.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Frequently Asked Questions About Calibrating Torque Wrenches<\/h2>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">How often does a torque wrench need to be calibrated?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">DIN EN ISO 6789 recommends 12 months or 5,000 activations, whichever comes first. In addition, a torque wrench should be calibrated immediately after being overloaded, dropped, or repaired.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">Can a torque wrench be adjusted?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">For many trigger-type torque wrenches, yes. If the deviation is outside the specified limits, we\u2019ll consult with you to determine whether an adjustment is advisable. Afterward, the wrench is recalibrated to document its new condition.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">How can I tell if my torque wrench is no longer accurate?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">Usually not at all\u2014and that\u2019s exactly the problem. The click sounds the same at 45 Nm as it does at 50 Nm. Only a calibration can show how much the set torque differs from the actual torque.<\/p>&#13;\n&#13;\n<h3 class=\"wp-block-heading\">How do I get my torque wrenches to QMK?<\/h3>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">By mail, in person, or via our <a href=\"https:\/\/qmk-gmbh.de\/en\/pick-up-and-delivery-service\/\">pickup and delivery service<\/a>.<\/p>&#13;\n&#13;\n<h2 class=\"wp-block-heading\">Have your torque wrenches calibrated at QMK<\/h2>&#13;\n&#13;\n<p class=\"wp-block-paragraph\">As a DAkkS-accredited calibration laboratory (D-K-20571-01-00) based in Offenburg, we calibrate torque wrenches from all major manufacturers\u2014both trigger-type and digital\u2014for use in workshops, assembly, and maintenance. Feel free to contact us.<\/p>&#13;\n","protected":false},"excerpt":{"rendered":"<p>With torque wrenches, a malfunction can be dangerous in both directions. We explain why the \u201cclick\u201d indicates the point of wear, how we calibrate torque wrenches according to DIN EN ISO 6789, and why 5,000 actuations are reached faster than you might think.<\/p>\n","protected":false},"author":2,"featured_media":4021,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[38],"tags":[],"class_list":["post-4042","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qmk-news-en","wpbf-post"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Calibrating Torque Wrenches \u2013 DIN EN ISO 6789, Interval &amp; Procedure | QMK GmbH<\/title>\n<meta name=\"description\" content=\"Calibrating torque wrenches in accordance with DIN EN ISO 6789: Test bench procedure, calibration interval of 12 months or 5,000 actuations, and practical tips from the QMK GmbH calibration laboratory.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Calibrating Torque Wrenches \u2013 DIN EN ISO 6789, Interval &amp; Procedure | QMK GmbH\" \/>\n<meta property=\"og:description\" content=\"Calibrating torque wrenches in accordance with DIN EN ISO 6789: Test bench procedure, calibration interval of 12 months or 5,000 actuations, and practical tips from the QMK GmbH calibration laboratory.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/\" \/>\n<meta property=\"og:site_name\" content=\"QMK GmbH\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-29T09:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-25T10:42:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"855\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Falko Krei\u00dfig\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Falko Krei\u00dfig\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/\"},\"author\":{\"name\":\"Falko Krei\u00dfig\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/person\\\/5e751ada4bb0092cb9d6c78c2310ba07\"},\"headline\":\"Calibrating a Torque Wrench: When the \u201cClick\u201d Is Off | #100Measuring Instruments No. 5\",\"datePublished\":\"2026-09-29T09:00:00+00:00\",\"dateModified\":\"2026-11-25T10:42:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/\"},\"wordCount\":885,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/drehmomentschluessel-kalibrieren-pruefstand.jpg\",\"articleSection\":[\"QMK News\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/\",\"name\":\"Calibrating Torque Wrenches \u2013 DIN EN ISO 6789, Interval & Procedure | QMK GmbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/drehmomentschluessel-kalibrieren-pruefstand.jpg\",\"datePublished\":\"2026-09-29T09:00:00+00:00\",\"dateModified\":\"2026-11-25T10:42:18+00:00\",\"description\":\"Calibrating torque wrenches in accordance with DIN EN ISO 6789: Test bench procedure, calibration interval of 12 months or 5,000 actuations, and practical tips from the QMK GmbH calibration laboratory.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/#primaryimage\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/drehmomentschluessel-kalibrieren-pruefstand.jpg\",\"contentUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/drehmomentschluessel-kalibrieren-pruefstand.jpg\",\"width\":1280,\"height\":855},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/home-page\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Calibrating a Torque Wrench: When the \u201cClick\u201d Is Off | #100Measuring Instruments No. 5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/\",\"name\":\"QMK GmbH\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#organization\",\"name\":\"QMK GmbH\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/QMK_Logo_Transparent.png\",\"contentUrl\":\"https:\\\/\\\/qmk-gmbh.de\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/QMK_Logo_Transparent.png\",\"width\":296,\"height\":89,\"caption\":\"QMK GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/#\\\/schema\\\/person\\\/5e751ada4bb0092cb9d6c78c2310ba07\",\"name\":\"Falko Krei\u00dfig\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g\",\"caption\":\"Falko Krei\u00dfig\"},\"url\":\"https:\\\/\\\/qmk-gmbh.de\\\/en\\\/author\\\/falko\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Calibrating Torque Wrenches \u2013 DIN EN ISO 6789, Interval & Procedure | QMK GmbH","description":"Calibrating torque wrenches in accordance with DIN EN ISO 6789: Test bench procedure, calibration interval of 12 months or 5,000 actuations, and practical tips from the QMK GmbH calibration laboratory.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/","og_locale":"en_US","og_type":"article","og_title":"Calibrating Torque Wrenches \u2013 DIN EN ISO 6789, Interval & Procedure | QMK GmbH","og_description":"Calibrating torque wrenches in accordance with DIN EN ISO 6789: Test bench procedure, calibration interval of 12 months or 5,000 actuations, and practical tips from the QMK GmbH calibration laboratory.","og_url":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/","og_site_name":"QMK GmbH","article_published_time":"2026-09-29T09:00:00+00:00","article_modified_time":"2026-11-25T10:42:18+00:00","og_image":[{"width":1280,"height":855,"url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand.jpg","type":"image\/jpeg"}],"author":"Falko Krei\u00dfig","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Falko Krei\u00dfig","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/#article","isPartOf":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/"},"author":{"name":"Falko Krei\u00dfig","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/person\/5e751ada4bb0092cb9d6c78c2310ba07"},"headline":"Calibrating a Torque Wrench: When the \u201cClick\u201d Is Off | #100Measuring Instruments No. 5","datePublished":"2026-09-29T09:00:00+00:00","dateModified":"2026-11-25T10:42:18+00:00","mainEntityOfPage":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/"},"wordCount":885,"commentCount":0,"publisher":{"@id":"https:\/\/qmk-gmbh.de\/en\/#organization"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/#primaryimage"},"thumbnailUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand.jpg","articleSection":["QMK News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/","url":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/","name":"Calibrating Torque Wrenches \u2013 DIN EN ISO 6789, Interval & Procedure | QMK GmbH","isPartOf":{"@id":"https:\/\/qmk-gmbh.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/#primaryimage"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/#primaryimage"},"thumbnailUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand.jpg","datePublished":"2026-09-29T09:00:00+00:00","dateModified":"2026-11-25T10:42:18+00:00","description":"Calibrating torque wrenches in accordance with DIN EN ISO 6789: Test bench procedure, calibration interval of 12 months or 5,000 actuations, and practical tips from the QMK GmbH calibration laboratory.","breadcrumb":{"@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/#primaryimage","url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand.jpg","contentUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand.jpg","width":1280,"height":855},{"@type":"BreadcrumbList","@id":"https:\/\/qmk-gmbh.de\/en\/calibrating-a-torque-wrench-when-the-click-is-off-100measuring-instruments-no-5\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/qmk-gmbh.de\/en\/home-page\/"},{"@type":"ListItem","position":2,"name":"Calibrating a Torque Wrench: When the \u201cClick\u201d Is Off | #100Measuring Instruments No. 5"}]},{"@type":"WebSite","@id":"https:\/\/qmk-gmbh.de\/en\/#website","url":"https:\/\/qmk-gmbh.de\/en\/","name":"QMK GmbH","description":"","publisher":{"@id":"https:\/\/qmk-gmbh.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/qmk-gmbh.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/qmk-gmbh.de\/en\/#organization","name":"QMK GmbH","url":"https:\/\/qmk-gmbh.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2022\/09\/QMK_Logo_Transparent.png","contentUrl":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2022\/09\/QMK_Logo_Transparent.png","width":296,"height":89,"caption":"QMK GmbH"},"image":{"@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/qmk-gmbh.de\/en\/#\/schema\/person\/5e751ada4bb0092cb9d6c78c2310ba07","name":"Falko Krei\u00dfig","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6c9a06b4a037d6d1cdbe940502d000e076c89165867b170fc1abc34a428c574f?s=96&d=mm&r=g","caption":"Falko Krei\u00dfig"},"url":"https:\/\/qmk-gmbh.de\/en\/author\/falko\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/qmk-gmbh.de\/wp-content\/uploads\/2026\/11\/drehmomentschluessel-kalibrieren-pruefstand.jpg","_links":{"self":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/4042","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/comments?post=4042"}],"version-history":[{"count":1,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/4042\/revisions"}],"predecessor-version":[{"id":4043,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/posts\/4042\/revisions\/4043"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/media\/4021"}],"wp:attachment":[{"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/media?parent=4042"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/categories?post=4042"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qmk-gmbh.de\/en\/wp-json\/wp\/v2\/tags?post=4042"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}