• Home page
  • QMK News
  • Calibrating a Torque Wrench: When the “Click” Is Off | #100Measuring Instruments No. 5

Calibrating a Torque Wrench: When the “Click” Is Off | #100Measuring Instruments No. 5

In our #100Messmittel series, we’re showcasing 100 measuring and testing devices that we calibrate every day at QMK. Following length and electrical properties, today we’re focusing on the third measurement parameter: torque.

🔧 With a torque wrench, an error in either direction is dangerous. Too little—and the connection comes loose. Too much—and the screw shears.

The tricky part: You hear the “click” and trust it. But that very click is the point of wear.

Measuring instrument No. 5 in our series: the torque wrench.

A torque wrench is calibrated on a torque test bench using software analysis
Torque wrenches put to the test: Here’s where we find out what that “click” is really worth.

What is a torque wrench?

A torque wrench applies a defined tightening torque—measured in newton-meters (Nm). In the classic click-type design, a spring mechanism triggers a noticeable click when the set value is reached. And that’s where the weakness lies: springs and tension elements wear out. A wrench that sits coiled in a toolbox for years and triggers daily will slowly lose its calibration. The set torque and the actual torque drift apart—without you even noticing.

Indicating or snapping: the two basic types

DIN EN ISO 6789 distinguishes between two types:

  • Type I – indicating torque wrenches: They display the applied torque, e.g., via a scale, a dial gauge, or a display.
  • Type II – triggering torque wrenches: They trigger when the set value is reached—usually with the characteristic “click.” This is the type most commonly found in workshops.
Reversible torque wrench with reversible ratchet in a case
A workshop classic: the ratchet torque wrench.

How do we calibrate a torque wrench?

On a torque test bench against a traceable reference transducer. We apply several setpoints across the measurement range and record the actual deviation at each point—in accordance with the standard and with defined repetition, since operator variation also affects torque readings. The calibration certificate then states in black and white exactly what the wrench does at “50 Nm.”

The torque wrench is placed on a reference torque transducer for calibration.
The reference transducer measures the actual torque present at the moment of release.

An overview of the procedure:

  1. Visual and functional inspection: Condition of the ratchet, square drive, scale, and adjustment mechanism.
  2. Preload: Before the actual measurement, the wrench is loaded several times to its maximum value so that the mechanism “settles in.”
  3. Measurement at multiple test points: typically at the lower, middle, and upper ranges of the scale, with multiple repetitions at each point.
  4. Evaluation: Deviation from the set value and measurement uncertainty for each test point; upon request, with an assessment against the permissible limit values specified in the standard.
  5. Documentation in the calibration certificate.

The basis is DIN EN ISO 6789: Part 1 specifies the requirements for torque screwdrivers, while Part 2 describes calibration and the determination of measurement uncertainty. You can find more information on traceability and measurement uncertainty in the QMK Calibration Glossary.

Where are torque wrenches used in practice?

Anywhere a bolted joint is safety-critical: in automotive workshops for wheel nuts and drivetrain components, in assembly for flanges, bearing caps, and housings, and on equipment for safety-critical bolted joints. In quality assurance and service, the specified tightening torque is often a parameter that must be documented. “Tight by hand plus a feel for it” simply isn’t enough.

Various torque wrenches in a transport case prior to calibration
We have already calibrated 8,694 different torque screwdrivers.

Fun Fact: You’ll reach 5,000 activations faster than you think

DIN EN ISO 6789 recommends recalibration after 12 months or 5,000 actuations—whichever comes first. And that happens faster than you think: With five wheel bolts per vehicle, 5,000 load cycles are reached after just 250 vehicles. A busy auto repair shop will therefore often hit that limit long before the 12 months are up.

Tip: Release the tension on the ratchet wrench after use

Trigger-type torque wrenches should be reset to the lowest scale value after use—but not below zero. This prevents the spring from being stored under constant tension and slows down spring fatigue. Otherwise, a wrench that sits in a case set to 200 Nm for months on end will gradually lose its accuracy.

A tool designed to ensure safety must know its own force. Otherwise, you’ll tighten with great confidence—but with the wrong torque.

Frequently Asked Questions About Calibrating Torque Wrenches

How often does a torque wrench need to be calibrated?

DIN EN ISO 6789 recommends 12 months or 5,000 activations, whichever comes first. In addition, a torque wrench should be calibrated immediately after being overloaded, dropped, or repaired.

Can a torque wrench be adjusted?

For many trigger-type torque wrenches, yes. If the deviation is outside the specified limits, we’ll consult with you to determine whether an adjustment is advisable. Afterward, the wrench is recalibrated to document its new condition.

How can I tell if my torque wrench is no longer accurate?

Usually not at all—and that’s exactly the problem. The click sounds the same at 45 Nm as it does at 50 Nm. Only a calibration can show how much the set torque differs from the actual torque.

How do I get my torque wrenches to QMK?

By mail, in person, or via our pickup and delivery service.

Have your torque wrenches calibrated at QMK

As a DAkkS-accredited calibration laboratory (D-K-20571-01-00) based in Offenburg, we calibrate torque wrenches from all major manufacturers—both trigger-type and digital—for use in workshops, assembly, and maintenance. Feel free to contact us.

Share post now:

Express calibration

Sometimes it can't go fast enough. This is exactly what our express calibration is for.

Your calibration request